AI Cure is a research tool showing open data. Not medical advice. Discuss with your doctor. Terms

← Trials
🧪

HANGZHOU Solution in Bicuspid AS Undergoing TAVR

RecruitingNAAges 60 Years - anyAllSecond Affiliated Hospital, Zhejiang University, …
💬

In plain words

What the trial is, and whether it could suit you

To compare supra-annular sizing and THV implantation technique (Hangzhou solution) versus annular sizing and THV implantation technique (control group) in bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding valves (SEVs): a randomized superiority trial

Sign in to get the eligibility rules as simple questions to take to your doctor.

📋 Eligibility rules (as published)
Inclusion Criteria: * Age ≥ 65 years * Age \<65 years and age ≥ 60 years with high surgical risk after combing STS Risk Estimate, Katz activities of Daily Living, major Organ System Dysfunction and Procedure-Specific Impediment; * Severe, bicuspid aortic stenosis: * Mean gradient ≥40 mmHg * Maximal aortic valve velocity ≥4.0 m/sec * Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2) * NYHA classification ≥ II; * Type 0, type 1 (Sievers classification) by MDCT * Perimeter-derived annulus diameter ranges from 20.0 mm to 29.0 mm; * Transfemoral TAVR * The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board (IRB)/Ethics Committee (EC) of the respective clinical site. Exclusion Criteria: * Any contra-indication for Self-expanding bioprosthetic aortic valve deployment * Leukopenia (WBC \< 3000 cell/mL), acute anemia (Hgb \< 9 g/dL), Thrombocytopenia (Plt\< 50,000 cell/mL). * Active sepsis, including active bacterial endocarditis with or without treatment; * Evidence of an acute myocardial infarction ≤ 1 month (30 days) before the intended treatment \[(defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)\]. * Stroke or transient ischemic attack (TIA) within 3 months (90 days) of the procedure. * Estimated life expectancy \< 12 months (365 days) due to carcinomas, chronic liver disease, chronic renal disease or chronic end stage pulmonary disease. * Any Emergent surgery required before TAVR procedure. * A known hypersensitivity or contraindication to any of the following that cannot be adequately medicated:aspirin or heparin (HIT/HITTS) and bivalirudin, clopidogrel,Nitinol (titanium or nickel),contrast media * Gastrointestinal (GI) bleeding that would preclude anticoagulation. * Subject refuses a blood transfusion. * Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits). * Other medical, social, or psychological conditions that in the opinion of the investigator precludes the subject from appropriate consent or adherence to the protocol required follow-up exams. * Currently participating in an investigational drug or another device study (excluding registries). * Hypertrophic cardiomyopathy (HCM with myocardium more than 1.5cm without an identifiable cause) with obstruction (HOCM). * Echocardiographic evidence of intracardiac mass, thrombus or vegetation. * Severe mitral stenosis amenable to surgical replacement or repair. * Aortic valve type cannot be determined (Sievers classification). * Significant aortic disease, including marked tortuosity (hyperacute bend), aortic arch atheroma \[especially if thick (\> 5 mm), protruding or ulcerated\] or narrowing (especially with calcification and surface irregularities) of the abdominal or thoracic aorta, severe"unfolding" and horizontal aorta(Annular Angulation\>70°). * Ascending aorta diameter \> 50 mm. * Aortic or iliofemoral vessel characteristics that would preclude safe placement of the introducer sheath. * Patient is considered high risk for TAVR by CT corelab, including coronary obstruction, annular rupture and other severe TAVR-Related complications. * Previous pacemaker implantation.
💊

What it tests

  • TAVR with Venus A plus using supra-annular sizing and THV implantation technique (Hangzhou solution)
  • TAVR with Venus A plus using annular sizing and THV implantation technique
📍

Where

18 sites
The First affiliated hospital of bengbu medical college
Bengbu, China
The General Hospital of the People's Liberation Army
Beijing, China
Fujian Medical University Union Hospital
Fuzhou, China
Xiamen University Affiliated Cardiovascular Hospital
Xiamen, China
Guangdong People's Hospital
Guangzhou, China
Zhengzhou Cardiovascular Hospital
Zhengzhou, China
The First Affiliated Hospital of Zhengzhou University
Zhengzhou, China
Hennan Provincial Chest Hospital
Zhengzhou, China

…and 10 more on ClinicalTrials.gov.

🤝 Taking part is your choice, and you can leave at any time. Only the trial team can confirm you are eligible — always decide together with your own doctor.
🛡️

AI Cure shows public evidence (Open Targets, ClinicalTrials.gov, PubMed, openFDA, DepMap, AlphaFold) with its source, and AI summaries that cite it — not medical advice and not a cure. Treatment decisions belong with your doctor. Research ideas are shared only with approved researchers and labs, who can test them. In an emergency call your local emergency number (112 in India and Europe, 911 in the US). AI Cure Terms of Use · Privacy