A Single-arm, Pivotal Study to Evaluate Acute Device and Technical Success of the CGuard Prime Carotid Stent System When Used in Conjunction to the ENROUTE Transcarotid Neuroprotection System in Patients Undergoing Carotid Artery Stenting Via the Transcarotid Artery Revascularization Approach

RecruitingNAAges 18 Years - 79 YearsAllInspireMD
💬

In plain words

What the trial is, and whether it could suit you

The objective of this study is to evaluate acute device and technical success of the CGuard Prime™ Carotid Stent System (80cm) when used in conjunction with the Enroute NPS during Transcarotid Artery Revascularization procedures in the treatment of carotid artery stenosis in spatients at high risk for adverse events from carotid endarterectomy.

Sign in to get the eligibility rules as simple questions to take to your doctor.

📋 Eligibility rules (as published)
INCLUSION CRITERIA: Candidates for participation in the study must meet all of the following general inclusion criteria. * Patient is ≥ 18 years and \< 80 years of age. * Patient is willing and able to provide appropriate study-specific informed consent, follow protocol procedures, and comply with follow-up visit requirements. * Patient is diagnosed with carotid artery disease treatable with a Carotid Artery Stent via a Transcarotid Artery Revascularization approach and is either symptomatic or asymptomatic, defined as: * Symptomatic carotid stenosis ≥ 50%. Symptomatic is defined as amaurosis fugax, transient ischemia attack (TIA) or stroke within the last 6 months ipsilateral to the side of the stenosis Or * Asymptomatic carotid stenosis ≥ 80% * High Risk condition for CEA: at least one, as shown below: Comorbid conditions: * Age ≥ 70 (maximum 80 years) * CCS angina class 3-4 or unstable angina * Congestive Heart Failure (CHF) NYHA class III-IV * Left ventricular ejection fraction (LVEF) ≤ 35% * MI ≥ 72 hours and \< 6 weeks pre-procedure * Multi-vessel CAD (≥ 2 vessels \>70% stenosis) and history of angina * Chronic Obstructive Pulmonary Disease (COPD) with FEV1\<50 * Permanent contralateral cranial nerve injury/paralysis * Restenosis from previous carotid endarterectomy (CEA) * Planned coronary artery bypass grafting (CABG) or valve replacement surgery between 31-60 days after CAS * Abdominal aortic aneurysm surgical repair or Endovascular repair is planned between 31 to 60 days after CAS. Anatomic conditions: * Occlusion of the contralateral CCA or ICA. * Prior radiation treatment to the neck or a radical neck dissection. * Severe bilateral ICA stenosis requiring treatment. * Target lesion at or above the level of the jaw (C2) or below the clavicle. * Severe tandem lesions * Inability to extend the neck due to cervical disorders. * Laryngeal palsy or laryngectomy. * Prior head and neck surgery in the region of the carotid artery. * Tracheostomy or tracheostoma. * Spinal immobility of the neck. * Hostile neck or surgically inaccessible lesion. * Target vessel and lesion meet all requirements for the CGuard Prime™ 80 stent: * Target lesion location at the carotid bifurcation and/or proximal internal carotid artery (ICA) * The diameter at the stent landing zone is between 4.8 mm and 9.0 mm. * The target lesion length is ≤ 36 mm and can be covered by a single CGuard Prime™ 80 stent. * Patient must have a 5 cm long disease-free segment of the common carotid artery (CCA) measured from the clavicle to the carotid bifurcation, with a minimum vessel diameter of 6 mm suitable for vascular access, sheath insertion, and vessel clamping. EXCLUSION CRITERIA: Patients are not eligible for the study if they have any of the following exclusion criteria. * Patient had or will have an interventional procedure or surgery of the carotid, coronary or peripheral arteries within 30 days before or after the index carotid procedure. * Patient had or will have open heart surgery or valvular intervention (percutaneous or surgical), or any major operation, within 30 days before or after the index carotid procedure. * Vascular anatomy that would preclude safe sheath insertion or deliverability of stent * Patient had a previously placed stent in the ipsilateral ICA or CCA. * Total occlusion or presence of a "string sign" of the ipsilateral ICA or CCA. * Presence of a filling defect of the target lesion. * Tandem lesions, which cannot be covered by a single CGuard Prime™ stent. * Patient has a stenosis of the innominate artery or proximal CCA requiring revascularization * Patient has an open neck stoma. * Patient has a history of bleeding diatheses or coagulopathy. * Patient has hypercoagulable state. * Patient has an alternative source of cerebral embolus, including but not limited to: 1. Chronic atrial fibrillation. 2. Episode(s) of paroxysmal atrial fibrillation within the past 6 months or history of paroxysmal atrial fibrillation requiring chronic anticoagulation. 3. Knowledge of cardiac sources of embolus (e.g. left ventricular aneurysm, intracardiac filling defect, cardiomyopathy, aortic or mitral prosthetic heart valve, calcific aortic stenosis, endocarditis, mitral stenosis, atrial septal defect, atrial septal aneurysm, or left atrial myxoma). 4. Recently (\<60 days) implanted heart valve (either surgically or endovascularly) as a known source of emboli as confirmed on echocardiogram, 5. Abnormal angiographic findings: ipsilateral intracranial or extracranial arterial stenosis (as determined by angiography or CTA/MRA 6 months prior to index procedure) greater in severity than the lesion to be treated; cerebral aneurysm \> 5mm; AVM (arteriovenous malformation) of the cerebral vasculature, or other abnormal angiographic findings. * Patient has a known sensitivity or allergy to nickel or titanium. * Patient has a sensitivity to contrast media that cannot be adequately pre-treated. * Patient has a sensitivity to both forms of protocol-acceptable anticoagulation strategies (i.e., both heparin AND Bivalirudin) * Patient has a sensitivity to an antiplatelet agent AND all protocol acceptable alternative antiplatelet options * Patient has a known intolerance to statins. * Patient has a life expectancy of less than 3 years from the date of enrollment as determined by the Wallaert Life Expectancy Scale * Patient has malignancy, primary or recurrent, and does not have independent assessment of life expectancy performed by the treating oncologist or an appropriate specialist other than the physician performing TCAR. * Patient has an evolving stroke or intracranial hemorrhage, or a history of previous intracranial hemorrhage or brain surgery within the past 12 months. * Patient had a recent stroke (≤ 7 days) placing him/her at risk of a hemorrhagic conversion during the index procedure. * Patient has a history of a major stroke with a neurologic deficit (NIHSS of ≥ 15 or mRS ≥3). * Patient had a TIA or a
💊

What it tests

  • CGuard Prime 80cm stent system
📍

Where

8 sites
UC Davis Health
Sacramento, United States
Indiana University School of Medicine
Indianapolis, United States
Allina
Minneapolis, United States
Washington University School of Medicine
St Louis, United States
Benefis Health System
Great Falls, United States
Mount Sinai Hospital
New York, United States
University of Rochester
Rochester, United States
TriHealth
Cincinnati, United States
🤝 Taking part is your choice, and you can leave at any time. Only the trial team can confirm you are eligible — always decide together with your own doctor.
🛡️

AI Cure shows public evidence (Open Targets, ClinicalTrials.gov, PubMed, openFDA, DepMap, AlphaFold) with its source, and AI summaries that cite it — not medical advice and not a cure. Treatment decisions belong with your doctor. Research ideas are shared only with approved researchers and labs, who can test them. In an emergency call your local emergency number (112 in India and Europe, 911 in the US). AI Cure Terms of Use · Privacy